RisingNet Data Center - The Westin Building
Facility.
2001 Sixth Avenue
Seattle WA, 98121
USABuilding.
RisingNet data center facility is located in the heart of connectivity in the
Northwest, the Westin Building, Downtown Seattle
Washington. The building is also known as the Securities Building Technology
Center and facilities.
The Westin Building is one of the largest carrier hotels on the West coast of
the United States and
the premier telecommunications hub, POP and carrier hotel for the Pacific Northwest.
The building has the
world-class environment for mission-critical infrastructure and the
structural
engineering to withstand, earthquakes, and other natural disasters.
Connectivity.
The Westin Building is a state-of-the-art carrier neutral environment,
giving us the access to more than 150 providers
of high-bandwidth Internet access as well as telecom services and fiber
providers in a single location. Access virtually unlimited bandwidth
capabilities from DSL to multiple OC-192 and in between. The building also give
us access in the region through the extensive copper and fiber optic Meet-Me
rooms as well as interconnection to other networks or peer via the Seattle
Internet Exchange (SIX) and the Pacific Northwest Gigapop (PNWGP). The Westin
building is the home of the Northwest Network Access Point (NAP).
Meet-Me Rooms.
The Westin Building's Copper and Fiber Meet-Me Rooms (MMRs) are access
controlled, managed facilities where buyers and sellers of Broadband networks
offer interconnectivity to their backbones and diverse services. The MMRs are
state of the art areas centrally located within the building, facilitating easy
access to our new and existing high-rise and low-rise cable risers. The MMRs
allow us to cross connects with multiple Internet Service Providers or network
carriers. It is also allow us to exchange bandwidth with multiple ISP. The
interconnection of carriers to other networks in a central location is a highly
efficient and expanding a network's reach.
Power.
Our data center has the multiple layer of power
backup protection. The Multiple layers of reliability consisting of 2N redundant
industrial capacity power distribution systems, Three Grid power system from the
Seattle City Light,
N+1 redundancy,
diesel backup generators and UPS (uninterruptible
power supplies).
In some cases if the data center has the power spikes, power drops or power
failure, UPS units will kick in instantly and then switch to emergency backup
power. Therefore, there is no interruption in the flow of electricity to
computers. The redundant power in our facilities enable your
equipment to run continuously, even in the event of a major outage.
Climate Control.
Our datacenter is equipped with a superior monitored climate control cooling
system that ensures climate temperatures do not affect computing power. We use
the Air Conditioning (HVAC)
units maintain a
climate of 67 degrees (+/- 5).
The Humidity
30-60%
is also maintained
at optimal level to keep static electricity level to its minimum.
Fire, Life and Safety.
The Westin Building Telecommunications Facilities offer pre-action dry pipe
sprinkler system with computer and telecommunications rated smoke and heat
detection systems. FM 200 fire suppression systems are installed in some caged
areas.
Security.
On-site physical security offers 24x7 staffed checkpoints,
Alarm/Key Monitoring,
keycard access is required to all secured
areas of the building, Biometric scan and card key required for access to data center,
and all activity in/out of the building is recorded.
Continuous video recording of all entrances, corridors, and data facilities is
provided by closed-circuit cameras. All visitors to our data center must be
escorted by an RisingNet staff.
|
|
|